- open CodesysV2.3
- go to: Online/Communication Parameters
- select the communication channel to be edited
- double click the value of the field "Baudrate"
=> by double clicking the value, the baudrate value increments
NOTE: This field cannot be edited by typing in numbers! Only double clicking it will increment the baudrate value!
In order to correct the path to the communication DLL, you can manually edit the path by double clicking it and editing it.
Now the important part: you MUST then press ENTER!!! otherwise the change will not be set and the old path will remain!
Press OK and the new path is set.
Instructions:
- in Codesys select "Online / Communication Parameter"
- click "New"
- give the new connection a name
- select the type of connection (usually "STW_FF_CAN")
- click "OK"
- verify the path points to the correct file. If not, manually correct the path